Khoom
GG1A-12(F) Tsau yuam kev-Kev Tiv Thaiv High-Voltage Switchgear Txee
video
GG1A-12(F) Tsau yuam kev-Kev Tiv Thaiv High-Voltage Switchgear Txee

GG1A-12(F) Tsau yuam kev-Kev Tiv Thaiv High-Voltage Switchgear Txee

GG1A-12(F) Tsau yuam kev-Kev Tiv Thaiv High-Voltage Switchgear Txee yog ib qho kev txhim khu kev qha sab hauv HV switchgear thiab nruab nrab voltage hlau clad switchgear daws rau 3-10kV fais fab kev faib tshuab, muaj kev ruaj ntseg siab interlocking thiab kev ua haujlwm ruaj khov.

Product Overview

 

 

CovGG1A-12(F) Tsau yuam kev-Kev Tiv Thaiv High-Voltage Switchgear Txeeyog ibSab hauv HV switchgeartsim los rau kev txhim kho ruaj khov, ua kom muaj kev sib txuas ua ke ua tiav uas ua tau raws li "Tsib Tiv Thaiv" kev ruaj ntseg. Nws yog haum rau3-10kV peb-theem AC 50Hz fais fab tshuab, ua hauj lwm raws li ib tug txhim khu kev qha kev daws rau lub hwj chim txais thiab faib.

 

Qhov nomedium voltage hlau clad switchgearyog dav siv nyob rau hauv ib lub tshuab busbar thiab tuaj yeem txuas mus rau ib qho busbar nrog kev teeb tsa bypass. Raws li kev hloov kho GG1A-12F qauv, nws ua rawsGB / T11022cov qauv, kom ntseeg tau tias kev ua haujlwm ruaj khov, kev nyab xeeb siab, thiab kev cia siab rau kev ua haujlwm.

 

Environmental Adaptability

 

 

Ambient kub: Max +40 degree, Min -15℃(hauv tsev)

 

Qhov siab: Tsawg dua lossis sib npaug li 1000m

 

txheeb ze humidity:

  • Lub hli nruab nrab Tsawg dua lossis sib npaug li 90% (ntawm ± 25 degree)
  • Qhov nruab nrab txhua hnub Tsawg dua lossis sib npaug li 95% (ntawm ± 25 degree)

 

Seismic siv: Tsawg dua lossis sib npaug li 8 degree

 

Dawb los ntawm cov hmoov av conductive, corrosive gases, los yog rwb thaiv tsev - cov khoom puas

 

Tsis muaj hluav taws kub lossis tawg tsam ib puag ncig

 

Technical Specifications

 

 

Yam khoom Chav tsev Parameter
Rated Voltage kV ua 3.6 / 7.2 / 12
Rated Tam sim no A 630–3150
Peak Withstand Tam sim no kA 50 / 63 / 80 / 100
Luv -Lub Sijhawm Nrog Tam Sim No (4s) kA 20 / 25 / 31.5 / 40
Txoj kev ua haujlwm - Electromagnetic / Caij nplooj ntoos hlav- them
Qhov Loj (W × D × H) mm 1200 × 1200 × 3100 (tsawg dua lossis sib npaug rau 1600A) / 1540 × 1400 × 3100 (Ntau dua lossis sib npaug rau 2000A)

 

Khoom zoo

 

 

 Indoor HV switchgear

1. Cov qauv muaj zog thiab txhim khu kev qha

Tsim los nrog lub siab - lub zog welded ncej siv 50 × 50 × 5 lub kaum sab xis steel, kom ntseeg tau zoo heev rigidity thiab tsis kam mus deformation. High- zoo steel panels txhim khu corrosion kuj thiab tiv thaiv qib.

 

2. Muaj nuj nqi muab faib kom yooj yim tu

Clear compartmentalized tsim:

  • Sab laug sab: relay & ntsuas chamber
  • Nruab nrab: ua haujlwm vaj huam sib luag
  • Txoj cai: Terminal Chamber
  • Hauv qab: kaw contactor & fuse

Txhim kho kev txij nkawm zoo thiab txo kev ua haujlwm yuam kev.

3. Optimized Internal Layout

Sab saum toj rau Circuit Court breaker, qis seem rau cais thiab cable compartments. Kev sib cais ntawm lub hwj chim / tswj lub tshuab ua kom muaj kev nyab xeeb ntawm kev ua haujlwm.

 

4. Ua kom tiav "Tsib Tiv Thaiv" Interlocking
Ua- hauv kev sib cuam tshuam zoo tiv thaiv:

  • Kev ua haujlwm tsis zoo ntawm cov disconnectors
  • Nkag mus rau cov chaw nyob
  • Kev hloov pauv tsis raug

Ua kom muaj kev nyab xeeb siab tshaj plaws rau cov neeg ua haujlwm thiab cov khoom siv.

medium voltage metal clad switchgear

 

Khoom Dimensions thiab Cheebtsam

 

Product Dimensions And Components

 

GG-1A (F)
Daim duab pob txha yooj yim ntawm siab -voltage switchgear
1. Relay qhov rooj 2. Terminal room door 3. Operation board 4. Contactor room door 5. Main busbar insulator bracket 6. Door to door 7. Next door 8. Relay room 9. Lighting fixtures 10. Terminal room

 

 

OCustomization thiab Xaiv Phau Ntawv Qhia

 

 

Thov muab cov ntaub ntawv hauv qab no thaum xaj kom paub meej cov khoom sib txuam:

Main Circuit scheme naj npawb, main wiring system diagram, layout diagram, floor plan;

Pab txhawb Circuit Court thiab tswj Circuit Court wiring schematic daim duab, davhlau ya nyob twg thaiv layout;

Qauv, specification, thiab kom muaj nuj nqis ntawm cov khoom nyob rau hauv lub txee;

Seb puas yuav ntxiv ib qho surge arrester (circuit breaker handcart);

Seb puas yuav teeb tsa qhov ntsuas qhov ntsuas hluav taws xob;

Txee xim yuav tsum tau (yog tias tsis muaj kev thov tshwj xeeb, lub tuam txhab tus qauv yuav raug siv);

Ib puag ncig kev ua haujlwm tshwj xeeb lossis lwm yam kev xav tau.

 

Daim ntawv thov

 

 

Qhov noSab hauv HV switchgearyog dav siv nyob rau hauv:

 

1.Industrial thiab mining fais fab faib

 

2. Cov tsev lag luam (cov khw, tsev kho mob, tshav dav hlau)

 

3.Residential thiab municipal infrastructure

 

4.Retrofit ntawm cov qub faib tshuab

 

Nws yog ib qho zoo tagnrhomedium voltage hlau clad switchgearkev daws teeb meem rau kev nyab xeeb, ruaj khov, thiab tus nqi- faib hluav taws xob zoo.

 

Peb lub tuam txhab

 

 

Zhejiang Gangheng Electric Co., Ltd

Zhejiang Gangheng Electric Co., Ltd., tsim nyob rau hauv 2004, yog lub teb chaws siab -tech enterprise specializing nyob rau hauv R&D, ntau lawm, muag, thiab kev pab tswv yim ntawm high-voltage hluav taws xob khoom (switchgear) thiab transformers. Lub tuam txhab nyob hauv Sidu Town, Jiangshan City, Zhejiang Province, uas nyob ib sab ntawm National Highway 205, Zhejiang-Jiangxi Railway, thiab G3 Beijing-Taipei Expressway, muab kev thauj mus los yooj yim.

 

Lub tuam txhab muaj cov cuab yeej zoo CNC xuas nrig ntaus tshuab, laser txiav tshuab, tooj liab bar dabtsi yog khoov tshuab, thiab tag nrho cov khoom siv kuaj, nruj me ntsis ua raws li cov qauv thoob ntiaj teb thiab lub teb chaws hauv kev tsim khoom. Peb cov khoom suav nrogGG1A-12(F) Tsau yuam kev-Kev Tiv Thaiv High-Voltage Switchgear Txeethiab lwm tus. Peb tau teev npe nyob rau hauv State Grid e-kev lag luam platform thiab tuav ISO9001, ISO14001, thiab OHSAS18001 ntawv pov thawj, nrog rau cov ntaub ntawv ntsuam xyuas rau siab - cov khoom siv hluav taws xob thiab ntau daim ntawv pov thawj.

 

Peb cov khoom muag zoo thoob plaws hauv lub xeev thiab raug xa tawm mus rau lub tebchaws xws li Iran, Kyrgyzstan, Zimbabwe, thiab Tanzania. Peb ua raws li txoj cai ntawm "Kev vam meej ntawm kev lag luam los ntawm kev tshawb fawb thiab thev naus laus zis, Tsim kom muaj lub hom phiaj zoo," muab kev pabcuam puv - voj voog los ntawm kev cob qhia kev cob qhia rau tom qab - kev muag khoom. Nrog rau kev ua tau zoo, qhov dav tshaj plaws, tus nqi sib tw, thiab cov kev pabcuam zoo tshaj plaws, peb lub hom phiaj yog koj tus khub ntseeg siab hauv cov khoom siv fais fab.

switchgear manufacturer
 

FAQ

 

 

Q: 1. GG1A-12(F) Sab Hauv Tsev HV switchgear siv rau dab tsi?

A: GG1A-12(F) yog ib qho HV sab hauv tsev switchgear tsim los rau kev txais fais fab thiab xa tawm hauv 3-10kV hluav taws xob tshuab. Nws yog dav siv nyob rau hauv industrial nroj tsuag, coj mus muag vaj tse, thiab infrastructure tej yaam num.

Q: 2. Dab tsi yog "Tsib Tiv Thaiv" txhais li cas hauv qhov hloov pauv no?

A: "Tsib Tiv Thaiv" system hais txog kev nyab xeeb kev cuam tshuam uas tiv thaiv:
Kev ua haujlwm tsis raug ntawm cov disconnectors
Kaw nyob rau hauv load
Qhib hauv qab load
Nkag mus rau qhov chaw nyob
Grounding hloov misoperation
Qhov no ua kom muaj kev nyab xeeb siab tshaj plaws rau cov neeg ua haujlwm thiab cov khoom siv.

Q: 3. Puas yog qhov nruab nrab voltage hlau clad switchgear?

A: Yog, GG1A-12(F) belongs rau nruab nrab voltage hlau clad switchgear, featuring ib tug tag nrho enclosed hlau qauv nrog compartmentalized tsim rau txhim khu kev ruaj ntseg thiab kev cia siab.

Q: 4. Qhov kev hloov pauv no ua raws li cov qauv dab tsi?

A: Qhov nruab nrab voltage hlau clad switchgear ua raws li GB / T11022 thiab lwm yam kev cai thoob ntiaj teb, ua kom muaj kev ua haujlwm siab thiab kev ntseeg siab.

Q: 5. Dab tsi yog qhov yuav tsum tau ua ntawm kev teeb tsa ib puag ncig?

A: Qhov no Sab Hauv Tsev HV switchgear yog tsim rau sab hauv tsev yam tsis muaj:
Conductive plua plav
Corrosive gases
Hluav taws kub lossis tawg phom sij

Q: 6. Qhov no switchgear puas tuaj yeem hloov cov khoom qub GG-1A?

A: Yog lawm, GG1A-12(F) yog ib qho kev hloov kho tshiab ntawm GG-1A switchgear nrog kev txhim kho kev nyab xeeb, ua rau nws zoo tagnrho rau retrofit thiab upgrade tej yaam num.

Q: 7. Lub sijhawm xa khoom thiab tom qab -kev pabcuam yog dab tsi?

A: Lub sij hawm xa tuaj: 2-4 lub lis piam (nyob ntawm kev teeb tsa)
Kev pab txhawb nqa: muaj ua ntej thiab tom qab muag
Tom qab- kev pabcuam muag: kev taw qhia tej thaj chaw deb lossis ntawm - kev txhawb nqa ntawm qhov chaw yog tias xav tau

 

 

Cim npe nrov: gg1a-12(f) tsau yuam kev-kev tiv thaiv siab-voltage switchgear txee, Tuam Tshoj gg1a-12(f) tsau yuam kev-tiv thaiv high-voltage switchgear txee manufacturers, lwm tus neeg, Hoobkas

Xa kev nug