Koj xa tawm RFQ rau nees nkaum panels. Cov lus qhia tshwj xeeb hais txog IEC 62271-200, tab sis cov ntawv txuas ntxiv tau theej los ntawm tus kws pab tswv yim tus qauv quotes IEEE C37.20.2 clauses. Peb tus neeg muag khoom teb nrog peb tus nqi, thiab tsis muaj leej twg piav qhia vim li cas.

Qhov no tshwm sim feem ntau ntawm cov haujlwm hauv Middle East, Africa thiab Central Asia, qhov twg nyiaj txiag, cov kws pab tswv yim thiab cov khoom siv hauv zos txhua tus coj lawv tus qauv. Cov lus nug tsis tshua muaj "tus qauv twg zoo dua?" Nws yog "tus qauv twg yog kuv tiag tiag yuav mus?" Phau ntawv qhia no qhia yuav ua li cas nyeem ib qho kev sib xyaw-tus qauv kom cov lus sib piv.

 

info-1000-673

Gangheng Factory

 

 

Yog vim li cas tus txheej txheem tom qab koj qhov kev txiav txim tseem ceeb


 

IEC yog tsev neeg tus qauv thoob ntiaj teb, siv thoob plaws Tebchaws Europe, Middle East, Africa, Asia thiab Australia. ANSI/IEEE yog North American kev lig kev cai. Ob lub hom phiaj ntawm kev nyab xeeb, txhim khu kev qha khoom. Lawv txawv li cas lawv mus txog ntawd.

Ib txoj hauv kev yooj yim kom nco qab: IEC feem ntau yograws li kev ua haujlwm. Nws txhais tau hais tias cov cuab yeej yuav tsum tau ua dab tsi thiab qhov kev sim ua pov thawj nws. ANSI/IEEE ntau duatsim-prescriptive. Nws nyiam hais txog kev tsim kho cov ntsiab lus xws li kev thaiv, shutters thiab hom breaker.

Tias yog vim li cas lub vaj huam sib luag uas dhau ib qho kev xeem hom kev xeem tsis tau txais los ntawm lwm qhov. Ob qhov kev ntsuam xyuas thiab cov txheej txheem xeem tsis hloov pauv. Yog tias koj qhov kev sib tw hais txog ob qho tib si, koj yuav tsum txiav txim siab seb tus twg yuav tswj hwm tus nqi ua ntej sib piv cov nqi.

 

Plaub qhov txawv uas hloov koj cov lus


 

Ntau cov ntawv sau ntau ntau qhov sib txawv. Hauv kev xyaum plaub ntawm lawv txav tus nqi, lub sijhawm ua haujlwm lossis kev lees txais.

1. Cov chav kawm voltage thiab qib rwb thaiv tsev

IEC ntsuas cov cuab yeej los ntawm qhov hluav taws xob siab tshaj plaws rau cov khoom siv (Um), nyob rau hauv ib qho ntawm 12, 24 thiab 40.5 kV. ANSI/IEEE siv cov chav kawm nominal voltage xws li 5, 15, 27 thiab 38 kV.

Cov ladders no tsis line up neatly. Ib qho 12 kV IEC vaj huam sib luag tsis yog tib yam li 15 kV-chav kawm ANSI vaj huam sib luag, thiab cov qib ntsuas hluav taws xob sib txawv. Raws li cov lus qhia ntxhib, 15 kV-chav kawm cov cuab yeej raug sim mus rau theem pib impulse (BIL, xob laim-impulse withstand voltage) ntawm 95 kV, thaum ib txwm 12 kV IEC vaj huam sib luag yog ntsuas ntawm 75 kV impulse. Tib qhov sib txawv muaj nyob nruab nrab ntawm 40.5 kV thiab 38 kV chav kawm. Ib txwm paub meej tias qhov tseeb tiv thaiv qhov tseem ceeb hauv qhov tshwj xeeb, tsis yog "kV" daim ntawv lo.

Cov lus qhia ntawm tus neeg yuav khoom: nug txog lub zog-zaus thiab impulse tiv thaiv qhov tseem ceeb ntawm tus lej. Yog tias daim ntawv tsuas yog hais tias "qhov nruab nrab voltage", nws tsis meej txaus los hais tawm.

 

2. System zaus

IEC cheeb tsam feem ntau khiav ntawm 50 Hz thiab North America ntawm 60 Hz. Ntau lub teb chaws siv ib tus qauv thaum khiav lwm zaus, yog li tsis txhob xav tias nws los ntawm tus qauv lub npe. Kev tsis sib haum xeeb cuam tshuam rau cov relays, motors thiab kev tiv thaiv kev teeb tsa. Nws yog ib lo lus nug pheej yig los nug ntxov thiab ib qho kim los teb tom qab xa khoom.

 

3. Kev tsim kho lub tswv yim

IEC 62271-200 cais cov hlau txuas nrog lub tshuab hluav taws xob los ntawm kev nkag mus tau yooj yim thiab los ntawm kev ua haujlwm sab hauv arc (muaj peev xwm muaj qhov cuam tshuam ntawm arc txhaum). Ob qho kev tsim kho thiab tshem tawm tau tso cai.

IEEE hlau-clad kev tsim kho yog nruj dua: tshem tawm cov khoom tawg, cov hlau thaiv hauv av ntawm cov khoom sib txuas, thiab cov kaw tsis siv neeg. Hauv kev xyaum ANSI-style iav nyiam qhov loj dua thiab hnyav dua, uas cuam tshuam rau kev thauj khoom, lub hauv paus thiab chav tsev loj.

Cov lus qhia ntawm tus neeg yuav khoom: yog tias qhov kev qhia tshwj xeeb hais tias "hlau-clad" lossis xav kom tshem tawm cov khoom tawg, cov qauv tsim kho yuav tsis tsim nyog, txawm tias nws daim ntawv pov thawj IEC.

 

4. Cov ntaub ntawv pov thawj

IEC hom kev xeem yog ua los ntawm cov neeg sawv cev tsim thiab sau tseg hauv cov ntawv xeem. IEEE muaj nws tus kheej tsim-kuaj ib ntus, thiab lub voj voog luv luv thiab cov kev xeem sib txawv. Ib hom kev xeem ntawv tshaj tawm nyob rau hauv ib tus qauv tsis sawv rau lwm tus. Nug seb tus qauv twg tau sau ntawv tawm tsam thiab lub chaw kuaj twg muab nws.

 

 

 

Hauv peb lub Hoobkas Jiangshan: los ntawm cov ntawv hlau mus rau kev sim switchgear.

 

 

Qhov teeb meem Mixed-Standard


 

Ib txoj haujlwm ntshiab IEC lossis ANSI ntshiab yog ib qho yooj yim los hais. Qhov teeb meem nyuaj yog qhov sib xyaw ua ke: IEC raws li kev siv tseem ceeb, ntxiv rau ANSI / IEEE (lossis BS) cov lus ntxiv los ntawm tus kws pab tswv yim lossis los ntawm kev siv hluav taws xob nrog kev coj ua qub txeeg qub teg.

Rau ib tus neeg muag khoom, txhua nqe lus ntxiv yuav txhais tau tias hloov kev tsim, teeb duab tshiab lossis kev sim tshiab. Rau tus neeg yuav khoom, qhov kev pheej hmoo yog cov neeg muag khoom ntsiag to txhais cov lus tsis meej pem hauv lawv tus kheej nyiam. Qhov pheej yig tshaj kev twv yuav tsuas yog ib qho uas tsis quav ntsej ib nrab ntawm cov lus qhia.

Peb qhov kev paub dhau los nrog cov haujlwm xa tawm yog tias cov khoob no tau daws pheej yig tshaj plaws ntawm RFQ theem, tsis yog ntawm lub Hoobkas lees txais. Gangheng Electric, nrog ntau tshaj 20 xyoo hauv cov khoom siv hluav taws xob, tsim los ntawm Suav GB / T cov qauv raws li nws cov hauv paus ntsiab lus thiab tuaj yeem ua haujlwm rau lwm cov kev cai xws li ANSI / IEEE lossis BS ntawm kev thov. Yog li ntawd peb pib txhua qhov kev nug xa tawm nrog cov lus sib piv-los ntawm nqe lus ua ntej hais. [Ceeb toom rau cov neeg siv khoom: thov paub meej tias cov khoom twg tuaj yeem ua tau thiab tsis tuaj yeem hloov kho rau ANSI / IEEE cov haujlwm.]

 

Matching Standard thiab Structure rau cov khoom zoo


 

Thaum tus txheej txheem tau teeb tsa, tus qauv ua raws. Ntawm no yog li cas hom vaj huam sib luag haum haum.

Tsau hom panels.Ib qho ruaj khov Hlau Enclosed Switchgear tsim haum rau cov haujlwm uas ua raws li IEC, xav tau cov hneev taw me me thiab muaj cov txheej txheem kev saib xyuas uas tso cai rau kev kaw. Piv txwv li, lub【XGN66-12(Z) tsau hlau enclosed switchgear】yog 12 kV sab hauv lub thawv-hom txee siv nyob rau hauv cov txheej txheem faib khoom siv.

Box-hom hlau-clad designs.Qhov twg ib qho kev qhia tshwj xeeb nug kom muaj kev sib cais ntau ntawm cov khoom tab sis tsis yog kev tsim kho kom tshem tau tag nrho, a【XGN15-12 lub thawv-hom hlau-clad switchgear】yog ib qho kev xaiv Medium Voltage Switchgear. Nws yog ib txwm muaj nyob rau hauv cov nplhaib-tseem ceeb thiab kev faib khoom siv.

Handcart (tshem tawm) designs.Yog tias qhov kev qhia tshwj xeeb xav kom tshem tau cov kev tshem tawm thiab kev sib cais yooj yim dua, txav mus rau tus tsim lub laub. Rau qib 40.5 kV, lub【GBC-40.5 handcart-type HV switchgear】npog qhov kev xav tau no. Lub tsheb thauj khoom tuaj yeem raug racked tawm mus rau qhov pom kev sib txuas, uas ua rau kev saib xyuas zoo dua thiab ua kom luv luv.

Tus qauv: qhov siab dua qhov voltage thiab qhov nruj dua qhov tshwj xeeb, qhov kev tsim kho yuav tsum tau ua ntau dua li qhov kev xaiv.

 

2

 

Gangheng Hlau Enclosed Switchgear

 

 

Cov ntaub ntawv siv tau: Ceev ntawm 40.5 kV Project


 

Cov txheej txheem kev sib tham tuaj yeem xav paub daws teeb meem txog thaum koj nyob ntawm qhov chaw. Hauv Tanzania, Gangheng muab KYN61-40.5 armored tshem tau HV Switchgear. Lub vev xaib tau mus los ntawm unboxing mus rau energization nyob rau hauv tsib hnub, thiab tus neeg siv khoom tus CEO tau sau ib daim vis dis aus ua tsaug. Cov lus qhia meej meej thiab cov ntaub ntawv tshawb xyuas ua ntej yog qhov ua tau zoo li qhov ua tau: thaum cov duab kos, kev ntsuam xyuas thiab cov ntawv xeem sib tw ua raws li qhov chaw xav tau, tsis muaj dab tsi los rov sib tham tom qab lub crates tuaj txog.

Tib txoj hauv kev tau txhawb nqa kev xa khoom mus rau Iran, Kyrgyzstan thiab Zimbabwe, thiab kev ua haujlwm hauv tsev rau cov neeg siv khoom hauv Suav teb. Cov lus qhia thoob plaws cov haujlwm no zoo ib yam. Cov qauv tsis ncua ib qhov project; cov qauv tsis daws teeb meem ua.

 

Kev Tswj Tus Nqi thiab Lead-Time: Ib Daim Ntawv Teev Cov Neeg Yuav Khoom


 

Siv xya lo lus nug no ua ntej koj lees txais ib nqe lus.

  • Tus txheej txheem twg tswj hwm yog tias ob qho kev tsis sib haum xeeb?Sau rau hauv RFQ.
  • Dab tsi yog qhov ntsuas qhov tseeb, lub zog zaus thiab impulse voltages?Cov naj npawb, tsis yog daim ntawv lo.
  • 50 Hz lossis 60 Hz?
  • Puas yog tshem tawm kev tsim kho yuav tsum tau ua?Cov qauv tsim kho feem ntau pheej yig dua thiab nrawm dua, yog li tsis txhob them rau qhov tsis xav tau.
  • Puas yuav tsum muaj kev faib tawm sab hauv arc, thiab mus rau qib twg?
  • Yam ntawv xeem twg yuav tsum tau, thiab raws li tus qauv twg?
  • Puas muaj qhov loj me lossis xim yuav tsum tsis yog tus qauv?Rau kev xav tau kev cai, nug seb tus neeg muag khoom puas them rau lawv.

Ntawm tus nqi, lub hauv paus ntsiab lus tseem ceeb los ntawm peb tus kheej tej yaam num yog qhov uas tsis yog-tus qauv configuration raug nqi tib yam li tus qauv rau tib cov khoom, tshwj tsis yog lub vaj huam sib luag nws tus kheej yuav tsum tau nthuav dav. Tsis muaj qhov tsawg kawg nkaus txiav txim kom muaj nuj nqis, yog li ib chav tsev tuaj yeem muab tau. Lub sij hawm txhuas nyob ntawm qhov kev txiav txim loj: kwv yees li 30 hnub rau kev txiav txim ib puag ncig USD 300,000, 45 hnub rau ib ncig ntawm USD 700,000 thiab 60 hnub rau ib ncig ntawm USD 1.5 lab. Cov qauv tsim kev cai feem ntau ntxiv rau qhov no, thiab nyob ib ncig ntawm 30 hnub ua haujlwm yog qhov kev npaj tsim nyog.

 

Xaus: Tig tus txheej txheem rau hauv ib txoj kab Specification


 

Lub IEC vs ANSI / IEEE kev sib cav tseem ceeb tsawg dua seb koj cov ntaub ntawv qhia meej tias koj tab tom yuav dab tsi. Ua ntej koj muab RFQ tom ntej:

Txiav txim siab tus txheej txheem tswj hwm thiab sau rau hauv thawj kab lus.

Sau cov voltage, zaus thiab rwb thaiv tsev qhov tseem ceeb raws li tus lej.

Qhia seb puas yuav tsum tau tshem tawm kev tsim kho.

Thov cov ntaub ntawv ntsuam xyuas hom thiab nug seb tus qauv twg lawv them.

Nug cov neeg xa khoom kom paub meej hauv kev sau ib nqe lus uas lawv tsis tuaj yeem ntsib.

Ua qhov no yuav siv sij hawm ib teev thiab feem ntau yuav txuag lub lis piam. Yog tias koj xav tau kev pab txhais cov lus qhia sib xyaw ua ke, xa mus rau peb pab neeg dhau los【hu rau Gangheng engineers】rau ib nqe lus-by-clause tshuaj xyuas ua ntej koj thov tus nqi.

 

FAQ


 

1. Dab tsi yog qhov txawv ntawm IEC thiab ANSI / IEEE switchgear?
IEC feem ntau yog kev ua haujlwm raws li kev ua haujlwm, thaum ANSI / IEEE yog cov ntawv sau ntau dua txog kev tsim kho. Lawv kuj siv cov kev ntsuas hluav taws xob sib txawv, cov txheej txheem xeem thiab cov ntsiab lus, yog li cov txiaj ntsig kev xeem tsis tuaj yeem hloov pauv ncaj qha.

2. IEC switchgear puas siv tau rau ntawm qhov project ANSI/IEEE?
Tsuas yog tias nws txaus siab rau qhov kev xav tau tshwj xeeb, uas feem ntau txhais tau tias kuaj xyuas cov chav kawm voltage, zaus, kev tsim kho thiab cov ntaub ntawv pov thawj. Tsis txhob xav tias ua raws li ib tus qauv npog rau lwm tus.

3. Qhov twg pheej yig dua, IEC lossis ANSI / IEEE switchgear?
ANSI-style iav feem ntau loj dua thiab siv cov khoom siv ntau dua, yog li nws feem ntau raug nqi ntau dua. Cov piv txwv tseeb nyob ntawm qhov project, thiab cov duab luam tawm sib txawv, yog li sib piv cov nqe lus tiag tiag es tsis yog cia siab rau qhov piv txwv.

4. Qhov txawv ntawm cov hlau-clad thiab hlau enclosed switchgear yog dab tsi?
Hlau-clad (IEEE) feem ntau txhais tau hais tias tshem tau cov kev tshem tawm thiab cov txheej txheem hauv nruab nrab ntawm cov chav. Hlau enclosed (IEC 62271-200) yog ib pawg dav uas suav nrog cov qauv tsim kho thiab tshem tawm, cais los ntawm kev nkag mus tau thiab kev ua haujlwm sab hauv.

5. Puas yog 12 kV tib yam li 15 kV switchgear?
Tsis yog . 12 kV yog qhov ntsuas IEC (qhov hluav taws xob siab tshaj plaws rau cov khoom siv) thiab 15 kV yog chav kawm ANSI voltage. Lawv cov kev ntsuas rwb thaiv tsev sib txawv, yog li paub meej tias qhov kev tiv thaiv qhov tseem ceeb ua ntej xaj.